Siemens S223 User Manual

Page of 381
UMN:CLI                                                                                                                                                              User  Manual 
SURPASS hiD 6615 S223/S323 R1.5 
42                                                                         A50010-Y3-C150-2-7619 
To disable password encryption, use the following command. 
Command Mode 
Description 
no service password-encryption
Global 
Disables password encryption. 
 
4.1.3 Changing 
Login 
Password 
To configure a password for created account, use the following command. 
Command Mode 
Description 
passwd
 [NAME
Global 
Configures a password for created account. 
 
The following is an example of changing password. 
SWITCH(config)# passwd Siemens 
Changing password for Siemens 
Enter the new password (minimum of 5, maximum of 8 characters) 
Please use a combination of upper and lower case letters and numbers. 
Enter new password:junior95 
Re-enter new password:junior95 
Password changed. 
SWITCH(config)# 
 
The password you are entering won’t be seen in the screen, so please be careful not to 
make mistake. 
 
4.1.4 
Management for System Account 
 
4.1.4.1 Creating 
System 
Account 
For the hiD 6615 S223/S323, the administrator can create a system account. In addition, 
it is possible to set the security level from 0 to 15 to enhance the system security. 
To create a system account, use the following command. 
Command Mode 
Description 
user add NAME DESCRIPTION 
Creates a system account. 
user add NAME  level
 <0-15> 
DESCRIPTION 
Global 
Creates a system account with a security level. 
 
The account of level 0 to level 14 without any configuring authority only can use exit and 
help
 in Privileged EXEC View mode and cannot access to Privileged EXEC Enable mode. 
The account with the highest level 15 has a read-write authority. 
 
 
 
i
!