Sony BKP-7933 User Manual

Page of 56
1-46 (E)
BKP-7933
1-10-2. Controlling a Waveform Monitor
A waveform monitor can be controlled from the MSU via the I/O PORT connector of the BKP-7933, by
setting the switches on the IF-689 board of the BKP-7933.
n
The following setting is effective to control a waveform monitor from the MSU that is connected to the
IF-480 board of the CNU-700 in which the BKP-7933 is installed.  A waveform monitor cannot be
controlled by the MSU that is connected to the optional IF-480 board (CNU IF board BKP-7930).
1.
Set the switch S2-2 on the IF-689 board to OFF.
When it is set to OFF, remote control mode of the waveform monitor is selected.
2.
Set the switch S2-3 on the IF-689 board in accordance with a waveform monitor in use.
HD ANALOG system waveform monitor (such as Tektronix 1730HD) 
→ 
ON
RECALL system waveform monitor 
 OFF
1-10. Using the BKP-7933 in the HD System
IF
RX TX
S-BUS
S-BUS ID No.
S2
CNU GROUP No.
+5
(Component side/A side)
IF-689 board