7.1.8.1 SNMP 
Trap 
Host 
To set an SNMP trap host, use the following command. 
Command Mode 
Description 
snmp trap-host 
IP-ADDRESS
 [COMMUNITY
snmp trap2-host 
IP-ADDRESS
 [COMMUNITY
Specifies IP address of an SNMP trap host. 
snmp inform-trap-host 
IP-ADDRESS
 [COMMUNITY
Global 
Specifies IP address of SNMP information trap host. 
 
You need to configure an SNMP trap host with the snmp trap2-host command, if you 
manage the switch via the ACI-E. 
To delete a specified SNMP trap host, use the following command. 
Command Mode 
Description 
no snmp trap-host
 IP-ADDRESS 
no snmp trap2-host IP-ADDRESS
 
Deletes a specified SNMP trap host. 
no snmp inform-trap-host IP-ADDRESS
 
Global 
Deletes a specified information trap host. 
 
You can set maximum 16 SNMP trap hosts with inputting one by one. 
 
The following is an example of setting an SNMP trap host. 
SWITCH(config)# snmp trap-host 10.1.1.3 
SWITCH(config)# snmp trap-host 20.1.1.5 
SWITCH(config)# snmp trap-host 30.1.1.2 
SWITCH(config)# 
 
7.1.8.2 SNMP 
Trap 
Mode 
To select an SNMP trap-mode, use the following command. 
Command Mode 
Description 
snmp trap-mode
  {alarm-report | 
event
Global 
Selects SNMP trap-mode according to user’s network 
environment. ( alarm-report or event) 
 
 
“event” trap-mode
 is set by default. It means that Dasan trap OID will be used upon 
 
sending the trap if the trap-mode is “event”   
 
“alarm-report” trap-mode 
will be used form SLE MIB OID which is Siemens private 
 OID. 
 
In order to manage hiD 6615 S223/S323 using ACI-E, the trap-mode must be set as 
“alarm-report”. Otherwise, ACI-E would not recognize any traps set from the hiD 6615 
S223/S323. 