32
Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001
Single Host With Eight Controller Units
Configured as Four Partner Groups
shows one application host connected through FC-AL cables to eight Sun
StorEdge T3+ arrays, forming four partner groups. This configuration is the
maximum allowed in a 72-inch cabinet. This configuration can be used for footprint
and I/O throughput.
Note –
This configuration is a recommended enterprise configuration for RAS
functionality because the controller is not a single point of failure.
The following three parameters must be set on the master controller unit, as follows:
mp_support = rw
or mpxio
cache mode = auto
cache mirroring = auto
Note –
For information on setting these parameters, refer to the Sun StorEdge T3 and
T3+ Array Administrator’s Guide.
Host-based multipathing software is required for this configuration.