Dynalink RTA1046VW User Manual

Page of 172
Wireless IAD User Manual 
 
136 
Therefore, when the log level is 
“Debugging” and the display level is 
“Error”, the CPE logs the most 
detailed message but shows error 
level data only. 
Mode:   
You can choose where to store the 
logs; the options include Local
Remote and BothLocal means the 
CPE, i.e., the wireless IAD. Remote 
means the log server you specified to 
forward the log information to. The 
default mode is Local.  
If you choose Remote or Both, you 
have to specify the Server IP 
Address 
and UDP Port, and all the 
events will be sent to the specified 
UDP port of the specified log server.   
Note:  
Display Level only filters for the local 
side. All the messages will be 
displayed on the remote Log Server. 
 
 
 
 
 
Example 
Suppose we are going to record the system logs on both the wireless IAD and the 
Server bearing IP address 10.11.95.2
, the procedures below illustrate the situation: 
   
System Log Configuration 
1. Choose 
Enabled Log.  
2. Select 
Debugging as the Log 
Level, and Error as the Display 
Level
. (Or select other level 
according to your needs.) 
3. Set 
the 
Mode as Both, key in the 
Server IP Address as 10.11.95.2
and leave the Server UDP Port 
as the default value 514
4. Press 
Apply to invoke the 
settings.