Specifications 
5.3  Power Requirements  
The AMC-S402 shall consume no more than the following from the system supplies 
under normal operating conditions. 
Table 9  Power Requirements 
Part number 
AMC-S402xxx 
 
Management Power 
(MP) 
100mA 
+12V (spin up < 100 
sec) 
1.5A (18W) 
+12v normal operating 
0.9A (10.8W) 
+12v (idle) 
0.5A (6W) 
OFF STATE 
LESS THAN 0.4W 
5.4  EMC Compliance 
This product was tested in an EMC-compliant chassis and meets the requirements 
for EN55022 Class A equipment. Compliance was achieved under the following 
conditions:  
  Conductive chassis rails connected to earth ground, providing the path for 
connecting shields to earth ground  
  Front panel screws properly tightened  
For minimum RF emissions, it is essential that the conditions above be 
implemented. Failure to do so could compromise the EMC compliance of the 
equipment containing the module.  
 