GarrettCom 6K32FR User Manual

Page of 75
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 
 
32 
www   GarrettCom   com
.
.
 
and the “Cable Loss” for 9/125 (Single-mode) is 0.25 dB/km(LXSC40) 
 
and the “Cable Loss” for 9/125 (Single-mode) is 0.2 dB/km (LXSC70)
 
The following data has been collected from component manufacturer’s (Agilent’s and 
Lucent’) web sites and catalogs to provide guidance to network designers and installers. 
Fiber  
Port 
Module 
Speed,  
 
Std. 
 
Mode
Std. 
km  
fdx 
(hdx)
Wave
-
length
nm 
Cable 
Size 
μ
X’mitr 
Output 
P
T ,
 dB 
R’cvr 
Sens.
P
R ,
dB
Worst 
OPB,
dB 
Worst* 
distance 
Km, fdx
typical
OPB,
dB 
typical*
distance
Km, fdx 
6KP4-
F10ST
 
10Mb 
FL 
Multi-
Mode
(2) 
850 
62.5/125
100/140
50/125 
-15.0 
-9.5 
-19.5 
-31 
-31 
-31 
14 
19.5 
19.5 
5.9 
3.4 
17 
23.5 
13.5 
6  
4.8 
6KPM- 
MST, MSC 
100Mb 
FX 
Multi-
mode
2 
(0.4) 
1300
62.5/125
50/125 
-20 
-23.5 
-31 
-31 
9.0 
5.5 
3.0 
2.0 
14 
12 
6KPM-SS
100Mb 
FX 
Single-
mode
18+ 
(0.4)  1300
9/125 -15 -31 14  28 
17.5 
35 
6KPM-
SSCL 
100Mb 
FX 
Single-
mode
40 
(0.4)  1300
9/125 -5 -34 
29  58 
32.5 
65 
6KPM- 
MTRJ 
100Mb 
FX 
Multi-
mode
2 
(0.4) 
1300
62.5/125
50/125 
-20 
-23.5 
-31 
-31 
9.0 
5.5 
3.0 
2.0 
15.8 
12.2 
5.5 
4.0 
6KPM-
MLC 
100Mb 
FX 
Multi-
mode
2 
(0.4)  1300 62.5/125
-19 -31 12 
16 
5.7 
6KPM-SLC 
100Mb 
FX 
Single-
Mode
15+ 
(0.4) 
1310
9/125 -15 -28 11  22 
GBIC-
SXSC 
1000Mb Multi-
mode
0.55 
 
850 62.5/125
50/125 
-9.5 -17 5.5 
12.5 
GBIC-
LXSC10 
1000Mb Single-
mode
10 
1300
9/125 
-9.5 -20 
8.5 
17 
10.5 
21 
GBIC-
LXSC25 
1000Mb Single-
mode
25 
1550
9/125 
-4.0 -21 
15 
37.5 17.5 43 
GBIC-
ZXSC40 
1000Mb Single-
mode
40 
1550
9/125 
-4.0 -21 
15 
60 17.5 
70 
GBIC-
ZXSC70 
1000Mb Single-
mode
70 
1550
9/125 
-3.0 -23 
18 
90 20.5 
102 
* Note:  The use of either multi-mode or single-mode fiber to operate at 100Mbps speed 
over long distances (i.e., in excess of  approx. 400 meters) can be achieved 
only
 
if the following factors are both applied: 
• 
The 100Mb fiber segment must operate in full-duplex (FDX) mode, i.e. the 
full-duplex (factory default) setting for 100Mbps fiber ports must be used. 
• 
The worst-case OPB of the fiber link must be greater than the fiber cable’s 
passive Attenuation. 
(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)