Grandstream Networks GXW40XX User Manual

Page of 38
 
Grandstream Networks, Inc. 
GXW40XX User Manual 
Page 36 of 38  
 
Firmware 1.0.4.2 
Last Updated:  06/2011 
 
S
OFTWARE 
U
PGRADE
 
  
Software upgrade can be done via either TFTP or HTTP/HTTPS. The corresponding configuration 
settings are in the ADVANCED SETTINGS configuration page. 
  
Firmware Upgrade through TFTP/HTTP/HTTPS 
 
To upgrade via TFTP or HTTP/HTTPS, the “Firmware Upgrade and Provisioning upgrade via” field needs 
to be set to TFTP, HTTP or HTTPS, respectively.  “Firmware Server Path” needs to be set to a valid URL 
of a TFTP or HTTP/HTTPS server, server name can be in either FQDN or IP address format. Here are 
examples of some valid URL.  
              firmware.mycompany.com:6688/Grandstream/1.0.4.2 
or 
 72.172.83.110 
  
NOTES: 
  Firmware upgrade  server in IP address format can be configured via IVR.  Please refer to the 
CONFIGURATION GUIDE section for instructions. If the server is in FQDN format, it must be set 
via the web configuration interface. 
 
  Grandstream recommends end-user use the Grandstream HTTP  server. Its address can be 
found at 
  . Currently the HTTP  firmware  server IP 
address  is 72.172.83.110.  For large  companies, we recommend to maintain their own TFTP/ 
HTTP/HTTPS server for upgrade and provisioning procedures. 
 
  Once a “Firmware Server Path” is set, user needs to update the settings and reboot the device. If 
the configured firmware server is found and a new code image is available, the GXW will attempt 
to retrieve the new image files by downloading them into the GXW400x  ’s SRAM. During this 
stage, the GXW’s LEDs will blink until the checking/downloading process is completed. Upon 
verification of checksum, the new code image will then be saved into the Flash. If 
TFTP/HTTP/HTTPS fails for any reason (e.g. TFTP/HTTP/HTTPS server is not responding, there 
are no code image files available for upgrade, or checksum test fails, etc), the GXW will stop the 
TFTP/HTTP/HTTPS process and simply boot using the existing code image in the flash.  
  Firmware upgrade may take as long as 15 to 30 minutes over Internet, or just 5 minutes if it is 
performed on a LAN.  It is recommended to conduct firmware upgrade in a controlled LAN 
environment if possible. For users who do not have a local firmware upgrade server, 
Grandstream provides a NAT-friendly TFTP server on the public Internet for firmware upgrade. 
  Grandstream’s latest firmware is availabl
 .  
Oversea users are strongly recommended to download the binary files and upgrade firmware 
locally in a controlled LAN environment.  
 
  Alternatively, user can download a free TFTP or HTTP server and conduct local firmware 
upgrade. A free windows version TFTP server is available for download from 
.  Our latest official release can be 
downloaded from http://www.grandstream.com/y-firmware.htm.  
 
 
Instructions for local firmware upgrade: 
 
1.  Unzip the file and put all of them under the root directory of the TFTP server.  
2.  Put the PC running the TFTP server and the GXW40XX device in the same LAN segment.