Gateway 9315 User Manual

Page of 168
41
www.gateway.com
Removing and installing air ducts, air 
dams, and baffle
Your server has been engineered to provide correct airflow in the chassis for sufficient 
cooling of drives, processors, and power supplies. As your server configuration changes, 
the airflow within the chassis will need to be modified to accommodate those changes.
Removing the processor air duct
The processor air duct normally covers the portion of the system board that includes the 
processor(s) and the memory. The duct will need to be removed if you need to add or 
remove a processor or memory in your system or if you need to replace the system board.
To remove the processor air duct:
1
Follow the instructions in 
. Make 
that sure you turn off the server, then unplug the power cord and all other cables 
connected to the server.
2
Follow the instructions in 
.
3
Lift the processor air duct from the chassis.
Caution
To ensure continued, reliable operation, always operate your server 
with the appropriate air ducts, air dams, and baffle in place. Failure 
to do this could result in equipment damage due to incorrect cooling.