Kentrox FE1 User Manual

Page of 4
Page 3
E1/FE1 Frame Monitoring DSU/CSUs
NETWORK INTERFACE
Line Rate
E1 (2048 Kbps) + 50 ppm
Framing
G.704
Line Code HDB3
Protocol
Clear Channel
Frame Relay
Line Impedance
120
Ω
 + 10
Ω
 at 1024 KHz
75
Ω
 + 10
Ω
 at 1024 KHz
Mechanical
DA15 socket for 120
Ω
Adapter for 75
Ω
 BNC
Lightning Protection
120
Ω 
interface withstands lightning
surges defined per FCC Part 68, and
unit recovers
TERMINAL INTERFACE (DataSMART 488)
Line Rate
E1 (2048 Kbps)  + 50 ppm
Framing
G.704
Line Code HDB3
Protocol
Clear Channel (DS0)
Line Impedance
120
Ω
 + 10
Ω
 at 1024 KHz
75
Ω
 + 10
Ω
 at 1024 KHz
Mechanical
DA15 socket for 120
Ω
Adapter for 75
Ω
 BNC
DATA PORT INTERFACE
Bit Rate
Nx64 kbps (N=1...31)
Electrical V.35 compatible
X.21 via adapter
V.11/X.27/EIA-530
Mechanical
DB25 socket
MANAGEMENT
Control Ports
DCE and DTE
EIA-574
DE9 socket
Daisy chain
38.4 kbps maximum
English menus
Async ASCII or SLIP/PPP
Ethernet Port
10Base-T RJ45 socket
Transmit and receive LEDs
SNMP Agent
MIB II (RFC 1213)
DS1/E1 MIB (RFC 1406)
Frame Relay MIB (RFC 1315)
Enterprise MIB*
TELNET server
Responds to Ping
Security filters
(for IP source addresses)
Up to 10 SNMP Trap hosts
In-band
From network or router
Shared or dedicated VC
Frame Relay or ATM DXI
LCD
Front panel display of unit status
Front panel configuration of unit
ALARMS
Traps
SNMP Traps via SLIP/PPP, Ethernet or
in-band
ASCII
Transmitted out async control port
FRAME RELAY CIRCUIT MANAGEMENT
Methodology
Non-intrusive, in-band
Virtual Circuit  (VC) Traffic
Group Measurements: % bandwidth
utilization, kbps, delays, VC status
(24 hour)
Detail: Frames, octets, kbps, delay
measurements, VC status
VC Status
Up, down, BECN set, FECN set,  DE set,
bandwidth utilization threshold exceeded,
delay threshold exceeded
VC Traffic Detail Measurement Intervals
Current/previous second; cur/prev 15
min; cur/prev 2 hour; cur 24 hour;
previous 7 complete days, 12 2-hour
intervals for current day
VC Delay Measurements
Maximum observed delay, average delay,
attempts made, measurement packets
lost Automatic delay measurements for
up to 64 active VCs
VC Delay Diagnostics
Round-trip VC delay via in-band
Frame Relay Performance Thresholds
User configurable
Access bandwidth utilization
Round-trip delay
Frame Relay Statistics
Non-integral number of octets
Invalid header address
Invalid HDLC FCS
Aborted frames
FPING responses lost (system total)
Reports
Frame statistical
Frame group (VC summary)
Frame individual (VC detail)
Frame VC utilization
Burst: data sent above CIR and above
excess burst rates
LOCAL LOOP DIAGNOSTICS
Loop Tests
Line loopback
Payload loopback
Data port loopback
Line Test Codes
2
23
-1, 2
15
-1, QRS, 3-in-24, 1-in-8, All 1s,
All 0s
Data Test Codes
511, 2047
BERT Tester
Independent BERT on all test codes
LOCAL LOOP
PERFORMANCE MONITORING
Data Storage
Last 24 hours of data in 15 minute
increments; last 7 days of data in
24-hour increments
Monitors
Network and terminal interface
Reports
Based on G.821 for performance
Far end
Alarm history
Network interface statistical
Terminal interface statistical
(add/drop only)
DIAGNOSTICS
LEDs
Power/fail
E1
Data port transmit
Data port receive
Data port CTS
Data port RTS
Loop Tests
Local loopback
Data terminal loopback
Terminal interface  loopback
(add/drop only)
STANDARDS
EN60590
EN55022 Class B
EN50081-2
ITU G.703, G.704, G.821
BABT NTR4, CTR 12, CTR 13
REGULATORY (Call for current status)
ACN
Australian Communications Authority and
Spectrum Management
BABT
NTR 4
CE
0682 _X_
TUV
GS
ENVIRONMENT
Operating 0° to 50° C
5% to 90% RH, non-condensing
Storage
-20° to 66° C
5% to 65% RH
POWER
AC
85-265 VAC, 47-63 Hz, 8W
PHYSICAL
Usage
Desktop or tray mount
Dimensions
19.68 cm W x 4.32 cm H x 29.21 cm D
Weight
1.14 kg (approx.)
*MIB files available at www.kentrox.com.
Specifications