14
 
DC Power Wiring, Replacing Power Supply Modules and Fans 
DC Power Supply Wiring Instructions 
The following diagram shows the wiring configurations for -48 VDC power supply 
modules for the iMediaChassis/6. 
 
User-Replaceable Power Supply Modules 
The iMediaChassis/6 ships from IMC Networks with one or two power supply 
modules installed depending on the model.  Chassis ordered with one power supply 
come with a filler tray installed in the second slot. 
To install a second power supply: 
1.  Remove the filler tray. 
2.  Slide the power supply module into the chassis and click into place. 
3.  Attach power cord. 
To remove a power supply module: 
1.  Disconnect the power source from the power supply. 
2.  Move the Power Supply Release switch toward the right and hold while grasping 
the power supply module by the silver handle. 
3.  Slide out of the chassis. (Power supply modules are hot-swappable.) 
4.  Install new power supply module. 
 
Fans 
Users can define a threshold for fan operation via SNMP (when installed in a 
managed environment).  If a fan’s speed falls below the specified level, SNMP sends a 
trap (configured in iView²) to the administrator.  There are also two LED indicators on 
the SNMP Management Module for fan failure. 
The red Reset Alarm Switch also functions as a Fan Test button.  To verify fan 
functionality, hold the button down for several seconds, the fans should engage.  The 
fans will turn off when the button is released.