Receiving and transmitting
D Repeater operation
Ask your dealer for details of the repeater’s program-
ming.
When the power is turned ON, the 
[PWR] indicator 
lights green. (p. 1)
The 
[TX] and [BUSY] indicators light simultane-
ously while transmitting/receiving a signal.
  • The 
[TX] indicator lights red.
  • The 
[BUSY] indicator lights green.
NOTE: A power amplifier protector is built-in to the 
repeater. The protector is activated when the re-
peater temperature becomes extremely high due 
to the frequently access to the repeater to reduce 
the transmit output power level. The output power 
will return to the normal level when the repeater 
has cooled down.
D Base station operation
Receiving
q
  Push 
[POWER] to turn the power ON.
w
 Set the audio and squelch levels.
  ➥  Rotate 
[SELECT]*
1
 fully counterclockwise in ad-
vance.
  ➥  Rotate 
[VOLUME] to adjust the audio output 
level.
  ➥  Rotate 
[SELECT]*
1
 clockwise until the noise 
disappears.
e
  Push 
[CH Up]*
2
 or 
[CH Down]*
2
 to select the de-
sired channel.
  •  When receiving a signal, the 
[BUSY] indicator lights 
green and audio is emitted from the speaker.
  •  Further adjustment of 
[VOLUME] to a comfortable lis-
tening level may be necessary at this point.
*
1
  When the [SQL Level Up/Down] key function is assigned 
to [SELECT].
*
2
  When the [CH Up]/[CH Down] key functions are as-
signed.
Transmitting
q
  Take the microphone off hook.
w
 Wait for the channel to become clear.
e
  Push and hold 
[PTT] to transmit, then speak into 
the microphone at your normal voice level.
r
 Release 
[PTT] to receive.
IMPORTANT: 
To maximize the audio quality of the transmitted sig-
nal:
(1) Pause briefly after pushing 
[PTT].
(2)  Hold the microphone 1 to 2 inch (2.5 to 5 cm) from 
your mouth, then speak into the microphone at a 
normal voice level.
3
7
OPERATION