IBM 4.3-W User Manual

Page of 516
Appendix A:  Configuration
452 
Netcool/Proviso Cisco IP Telephony Technology Pack User’s Guide, Version 4.3-W
15. Ensure that the Bulk input files can be read. 
To verify that the UBA application can read the Bulk input files, follow these steps: 
15-a. Place a Bulk input file at the source input location. 
—  (443 only) The source input location for Bulk input files is specified using the URI parameter from the 
pack’s XSD file, which you can view using the Topology Editor. 
—  (Pre-443 only) The source input location for Bulk input files is specified using the URI parameter from 
the template file, which you added to the 
dc.cfg
 file in a previous step. 
Within the configured file retrieval interval (typically, five minutes), the UBA application retrieves the 
Bulk input file and copies it to the following directory: 
DATA_CHANNEL_HOME
/UBA.<channel>.<collector>/<instance>/do/ 
where: 
The UBA application then processes the Bulk input file according to the instructions in the Bulk Adaptor 
Design File. 
Note:  
The first time that the UBA processes a Bulk input file, it passes a metric to the CME. The CME 
rejects this metric as a BAD_METRIC because the metric does not have an associated grouped sub-element prior 
to the time this metric is recorded. This is expected behavior. The CME accepts metrics from the Bulk input files 
after the inventory is run. 
15-b. Ensure that the UBA application can successfully read the Bulk input file you copied into the source 
input location by issuing a 
tail
 utility command similar to the following: 
The UBA application connects to the database. 
This event causes a message similar to the following to 
display: 
DB_CONNECT Connecting to <sid> as 
<user>
 
If you see this database connection message without prior 
errors, the UBA application has passed the syntax check. 
Event Meaning 
Variable Meaning 
DATA_CHANNEL_HOME 
Is /opt/datachannel
, by default. 
<channel> 
Specifies the channel number (for example, 1) you 
specified when configuring this DataChannel. 
<collector> 
Specifies the collector number (for example, 100) you 
specified when configuring this UBA Bulk Collector. 
<instance> (443 only) 
Specifies the string for the INSTANCES parameter in the 
pack’s XSD file. Typically, this string represents the name 
of the pack and is read-only. You can view the string 
specified for INSTANCES using the Topology Editor. 
<instance> (pre-443 only) 
Specifies the string for the INSTANCES parameter in the 
pack’s template file. You were instructed to copy this 
parameter to the dc.cfg file in a previous step.