Proxim AP-2000 User Manual

Page of 244
173
Using the Command Line Interface (CLI)
NOTE
The Heartbeat parameters are advanced settings not available via the HTTP interface. When Heartbeat is 
enabled, the AP periodically sends a message to the Syslog server to indicate that it is active. The frequency 
with which the heartbeat message is sent depends upon the setting of the Heartbeat Interval.
Syslog Host Table
The table described below configures the Syslog hosts that will receive message from the AP. You can configure up to 
ten Syslog hosts.
Bridge Parameters
Spanning Tree Parameters
Spanning Tree Priority and Path Cost Table
Syslog Lowest Priority 
Logged
Integer
1 – 7
1 = LOG_ALERT
2 = LOG_CRIT
3 = LOG_ERR
4 = LOG_WARNING
5 = LOG_NOTICE
6 = LOG_INFO (default)
7 = LOG_DEBUG
RW
syslogpritolog
Heartbeat Status
Integer
enable (1)
disable (2) (default)
RW
sysloghbstatus
Heartbeat Interval (seconds) Integer
1 – 604800 seconds;
900 sec. (default)
RW
sysloghbinterval
Name
Type
Values
Access
CLI Parameter
Syslog Host Table
Table
N/A
R
sysloghosttbl
Table Index
Integer
1 – 10
N/A
index
IP Address
IpAddress
User Defined
RW
ipaddr
Comment (optional)
DisplayString
User Defined
RW
cmt
Status (optional)
Integer
enable
disable
delete
RW
status
Name
Type
Values
Access
CLI Parameter
Spanning Tree
Group
N/A
R
stp
Spanning Tree Status
Integer
enable (default)
disable
RW
stpstatus
Bridge Priority
Integer
0 – 65535
32768 (default)
RW
stppriority
Maximum Age
Integer 
600 – 4000 
(in 0.01 sec intervals; 
i.e., 6 to 40 seconds)
2000 (default)
RW
stpmaxage
Hello Time
Integer
100 – 1000 
(in 0.01 sec intervals; 
i.e., 1 to 10 seconds)
200 (default)
RW
stphellotime
Forward Delay
Integer
400 – 3000 
(in 0.01 sec intervals; 
i.e., 4 to 30 seconds)
1500 (default)
RW
stpfwddelay
Name
Type
Values
Access
CLI Parameter
Spanning Tree Table
Table
N/A
R
stpbl
Table Index (Port)
N/A
1 – 15
R
index