Chapter 6  Troubleshooting and Diagnostics 
Installation and Operation Manual 
6-18 Testing 
ASMi-52
 
ASMi-52 Ver. 2.5 
ASMi-52 
Bert 
1. Bert 
 
(ON/OFF) 
2. Bert + RLB 
(ON/OFF) 
3. Bert pattern 
4. Save Bert parameters 
 
ESC-prev. menu ; !–main menu ; &–exit terminal  
Figure 6-16.  BERT Menu 
3.  From the Bert menu, select Bert Pattern (see 
Figure 6-16
). 
The Bert Pattern selection is displayed (see 
Figure 6-17).
 
ASMi-52 
Bert Pattern 
 2E15-1 
 Mark 
 Spare 
 Alternate 
 
ESC-prev. menu ; !–main menu ; &–exit terminal  
Figure 6-17.  BERT Pattern Menu 
 
To configure the BERT results: 
1.  From the Monitoring menu, select Physical Port Statistics (Main menu > 
Monitoring > Physical Port Statistics). 
The Physical Port Statistics menu is displayed, (see 
Figure 6-1
2.  From the Physical Port Statistics menu, select Bert Performance
The Bert Performance menu is displayed, (see 
Figure 6-18
). 
ASMi-52 
Bert Performances 
1. Bert results 
2. Inject single error local 
3. Inject single error remote 
4. Bert clear local performance 
5. Bert clear remote performance 
ESC-prev. menu; !–main menu ; &–exit terminal  
Figure 6-18.  Bert Performance Menu 
3.  From the Bert Performances menu, select Bert Results
The Bert Result window is displayed, (see 
Figure 6-19