  Improper Network Topologies 
 
It is important to make sure that the network topology is valid. Common topology faults 
include excessive cable length and too many repeaters (hubs) between end nodes. In 
addition, the user should make sure that the network topology contains no data path 
loops. Between any two ends nodes, there should be only one active cabling path at 
any  time.  Data  path  loops  will  cause  broadcast  storms  that  will  severely  impact  the 
network performance. 
 
 
Diagnosing LED Indicators 
 
To  assist  in  identifying  problems,  the  switch  can  be  easily  monitored  through  panel 
indicators, which describe common problems the user may encounter and where the 
user can find possible solutions. 
 
If the power indicator does turn on when the power cord is plugged in, the user may 
have  a  problem  with  power  outlet,  or  power  cord.  However,  if  the  switch  powers  off 
after running for a while check for loose power connections, power losses or surges at 
power outlet. If the problem still cannot be solved, please contact the local dealer for 
assistance. 
 
 
Diagnosing PoE problems 
 
  No Power Forward 
  Make sure the connected PD device complies with IEEE 802.3af standard. The 
PoE switch only supports the IEEE 802.3af compliant PD. 
  The PoE switch uses the signal power pair to forward power, the data and the 
power traverse the pin. Please check the documentation for your PD device to 
make  sure  the  power  pair  it  uses.  The  following  table  is  the  signal  power  pair 
RJ-45 port pin out: