Bosch D6100 User Manual

Page of 168
Conettix D6600/D6100 | Computer Interface Manual | 3.0  
Computer Communication Protocols 
 
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 
31 
 
 
3.2.4 
Ademco 4-2 Express (Message Type c) 
SIA Mode Description 
4-2 Express 
Example 
<LF><CRC><c><sequence#><receiver#><line#>[#aaaa|XY]<CR> 
 
Table 43: 
Ademco 4-2 Express (Message Type c) Byte Description 
 
Title Description 
LF 
Standard line feed character.  
CRC 
Cyclical redundancy check number.  
Message Type 
c  
sequence# 
The message sequence number. The valid sequence number range is 0001 to 9999. 
receiver# 
The receiver gateway that sent the message. Valid digits are 01 to 99 for the 
D6600/D6100. 
line# 
(Line/Group #) 
The line number of the line in the receiver gateway that sent the message. Valid digits are 00 
to 99. The receiver uses Line 0 (zero) for internal messages. 
account# 
The communicator's account number has four digits. 
XY 
Event code and Zone number.   
 
Figure 10:  Message sent to printer 
mm/ddshh:mmsLxxsE42sACCTsaaaasEVENT=XY
 
 
 
For lines that are grouped, Gxx appears 
instead of Lxx. 
 
Table 44: 
Ademco 4-2 Express (Message 
Type c) Printer Output 
 
Characters Description 
E42 
Ademco 4-2 Express format. 
Lxx:  
Line number. 
Gxx 
Grouped line numbers.