Bosch D6100 User Manual

Page of 168
Conettix D6600/D6100 | Computer Interface Manual | 3.0  
Computer Communication Protocols 
 
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 
37 
 
3.2.12  FBI Super Fast (Message Type F) 
SIA Mode Description 
FBI Super Fast 
Example 
<LF><CRC><F><sequence#><receiver#><line#>[#aaaa|TZZE]<CR> 
 
Table 57: 
FBI Super Fast (Message Type F) Byte Description 
 
Title Description 
LF 
Standard line feed character.  
CRC 
Cyclical redundancy check number.  
Message Type 
F  
sequence# 
The message sequence number. The valid sequence number range is 0001 to 9999.  
receiver# 
The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100.  
line# 
(Line/Group #) 
The line number of the line in the receiver gateway that sent the message. Valid digits are 00 
to 99. The receiver uses Line 0 (zero) for internal messages. 
account# 
The communicator's account number has four digits.  
Zone type.   
ZZ 
Zone number.   
Event type.   
 
Figure 16:  Message sent to printer 
mm/ddshh:mmsLxxsFBIsACCTsaaaasTZZE+++s
ACCsaaaastttttttttseeeeeeeesiisnnn 
 
 
For lines that are grouped, Gxx appears 
instead of Lxx. 
 
 
Table 58: 
FBI Super Fast (Message Type F) 
Printer Output 
 
Characters Description 
FBI 
FBI Super Fast format. 
Lxx: Line 
number. 
Gxx 
Grouped line numbers. 
 
 
Table 59: 
Event Code Table 
 
Code Zone/Event 
Type 
Fire 
2 Panic 
Burglary 
4 Medical 
Auxiliary 
6 Bypass 
Inactive 
8 Eight 
Nine 
0 Zero 
Opening 
C Closing 
Abort 
E Restore 
Trouble 
 
 
Table 60: 
Printer Output Codes 
 
Characters Description 
ii 
ZN=Zone number - ID=User ID 
nnn Zone/User 
number. 
ttttttttt 
Up to nine-character zone type, right 
justified FIRE, PANIC, BURGLARY, 
MEDICAL, AUXILIARY. 
eeeeeeee 
Up to eight-character event type, left 
justified ALARM, RESTORE, TROUBLE, 
OPEN, OPENGRP, CLOSE, CLOSEGRP, 
BYPASS, UN BYPASS, CANCEL.