Conettix D6600/D6100 | Computer Interface Manual | 3.0  
Computer Communication Protocols 
 
 
48 
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 
 
3.2.26  Telim (Message Type n)  
SIA Mode Description 
Telim Example 
<LF><CRC><n><sequence#><receiver#><line#>[#aaaaaa|EETTZZZZZZZZZZZZZZZZZZ]
<CR> 
 
Table 81: 
Telim (Message Type n) Byte Description 
 
Title Description 
LF 
Standard line feed character.  
CRC 
Cyclical redundancy check number.  
Message Type 
sequence# 
The message sequence number. The valid sequence number range is 0001 to 9999. 
receiver# 
The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100. 
line# 
(Line/Group #) 
The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 
99. The receiver uses Line 0 (zero) for internal messages. 
account # 
The communicator's account number has up to six digits. 
EETTZZZZZZZZZZZZZZZZ
ZZ
 
The event type and input line number.  
 
3.2.27  Varitech FSK 4-1  (Message Type <TAB>) 
SIA Mode Description 
Varitech FSK 4-1 
Example 
<LF><CRC><TAB><sequence#><receiver#><line#>[#aaaa|data]<CR> 
 
Table 82: 
Varitech FSK 4-1  (Message Type <TAB>) Byte Description 
 
Title Description 
LF 
Standard line feed character.  
CRC 
Cyclical redundancy check number.  
Message Type 
<TAB> 
sequence# 
The message sequence number. The valid sequence number range is 0001 to 9999.  
receiver# 
The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100. 
line# 
(Line/Group #) 
The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99 
The receiver uses Line 0 (zero) for internal messages. 
account# 
The communicator's account number has four digits. 
data
 
The event type and 1-digit zone number.