Brocade Communications Systems RFS6000 User Manual

Page of 36
Verifying the installation
4
22
Brocade Mobility RFS6000 Controller Installation Guide
53-1001573-03
CAUTION
.An improper shutdown can render the Mobility RFS6000 Controller 
inoperable such that it could require service by Brocade Support. Do 
not remove AC power without first following the shutdown procedure. 
An abrupt loss of power can corrupt the information stored on the 
device. 
Verifying the installation
View the LEDs on the front panel of the Mobility RFS6000 Controller to ensure the 
device is functioning properly. The normal LED pattern follows this path:
During the Power On Self Test (POST), the System 1 and System 2 LEDs both 
blink green.
If the POST test fails, the System 1 LED will blink amber. If the POST test 
succeeds, the System 1 LED will be lit solid green.
As the software is initialized, the System 2 LED will blink green.
After the software has finished initializing, the System 1 LED will be lit solid 
green and the bottom System 2 LED will be off. The Mobility RFS6000 
Controller is ready to be configured, as described in the Brocade Mobility RFS 
Controller System Reference Guide
.
Other LED codes indicate the presence (or absence) of different standby states, or 
errors. A guide to the Mobility RFS6000 Controller LEDs codes is provided in