Chapter 15 Remote Management
NBG410W3G Series User’s Guide
276
15.14.2  SNMP Traps 
The ZyXEL Device will send traps to the SNMP manager when any one of the following 
events occurs:
15.14.3  REMOTE MANAGEMENT: SNMP 
To change your ZyXEL Device’s SNMP settings, click ADVANCED REMOTE MGMT 
SNMP. The screen appears as shown.
Figure 176   ADVANCED > REMOTE MGMT > SNMP
Table 80   SNMP Traps
TRAP #
TRAP NAME
DESCRIPTION
0
coldStart (defined in RFC-1215)
A trap is sent after booting (power on).
1
warmStart (defined in RFC-
1215)
A trap is sent after booting (software reboot).
4
authenticationFailure (defined in 
RFC-1215)
A trap is sent to the manager when receiving any SNMP 
get or set requirements with the wrong community 
(password).
6
whyReboot (defined in ZYXEL-
MIB)
A trap is sent with the reason of restart before rebooting 
when the system is going to restart (warm start).
6a
For intentional reboot :
A trap is sent with the message "System reboot by user!" 
if reboot is done intentionally, (for example, download 
new files, CI command "sys reboot", etc.).
6b
For fatal error : 
A trap is sent with the message of the fatal code if the 
system reboots because of fatal errors.