ZyXEL Communications NSA-2401 User Manual

Page of 362
 Chapter 6 Storage Screens
NSA-2401 User’s Guide
135
• Down when an array is down and cannot be fixed. The array cannot be used and the data is 
lost. Replace the faulty disk(s) and recreate the array, volumes, and sharing configuration.
If an array is down, users can no longer transfer files to/from the array’s shares. If an array is 
degraded, then file transfer to/from the shares in the degraded array will be slower. 
"
Although there is no explicit message from CIFS that tells users an array is 
degraded or down, you can have the NSA send the administrator an email 
alert.
Resynchronizing and Reshaping
The NSA resynchronizes a RAID 1, RAID 5, or RAID 10 array to repair it. When you add a 
disk to a three-disk RAID 5 array, the NSA reshapes it into a four-disk RAID 5 array. 
Resynchronizing or reshaping an array is done block-by-block, so the time it takes depends on 
the size of your hard drive(s), not the amount of data you have on them.
"
Do not restart the NSA while the NSA is re-sychronizing or reshaping an array 
as this will cause the process to start over from the beginning again after the 
NSA fully reboots.
You can access data on a RAID array while the NSA is re-sychronizing or reshaping it, but it 
is not recommended. The performance will be slower and your data is at risk until the 
resychronization or reshaping is complete.
6.5  RAID Screen
Click Storage > Internal Storage  > RAID to display the RAID array summary screen as 
shown. Use this screen to manage the NSA RAID (and JBOD) arrays.
Figure 128   Storage > Internal Storage  > RAID