6.9.8  RAID and Data Protection
If a hard disk fails and you’re using a RAID 1, RAID 10, or RAID 5 array then your data will 
still be available (but at degraded speeds until you replace the hard disk that failed and re-
synchronize the array). However, RAID cannot protect against file corruption, virus attacks, 
files incorrectly deleted or modified, or the NSA malfunctioning. See 
 
for what you should use in these cases to protect data on your NSA.
6.9.9  S.M.A.R.T Attributes
The following table describes some common S.M.A.R.T. attributes. If a higher or lower raw 
attribute value is better, it is indicated in the BETTER column. Since S.M.A.R.T. attributes 
and their definitions vary by manufacturer, refer to the hard drive manufacturer for details 
about the attributes your hard drive supports. 
Table 42   S.M.A.R.T. Attributes 
ID
ATTRIBUTE 
NAME
BETTER
DESCRIPTION
01
Read Error Rate
Low
Shows the rate of hardware read errors. If this is not zero, there is 
a problem with the disk surface or the read/write heads. 
02
Throughput 
Performance 
High
This is the hard drive’s general (overall) throughput performance. 
A decreasing value indicates a problem.
03
Spin-Up Time 
Low
This is the average number of milliseconds the hard drive took for 
spindle spin up (from zero RPM to fully operational).  
04
Start/Stop Count
The total number of spindle start and stop cycles.
05
Reallocated 
Sectors Count
Low
Total number of reallocated sectors on the hard drive. When the 
hard drive detects a read/write/verification error, it marks the 
sector as “reallocated” and transfers the data to a specially 
reserved (spare) area. The process is also known as remapping 
with “reallocated” sectors known as remaps. The more sectors 
the hard drive has to reallocate, the slower read and write speeds 
become.
06
Read Channel 
Margin 
This is the margin of a channel when it reads data.
07
Seek Error Rate 
Low
This is the rate of the magnetic heads’ seek errors. A failure in the 
mechanical positioning system, such as servo damage or a 
thermal widening of the disk, results in seek errors. An increasing 
number of seek errors indicate the condition of the disk surface 
and the mechanical subsystem are worsening.
08
Seek Time 
Performance 
High
This is an average performance indicator for the seek operations 
of the magnetic heads. Mechanical subsystem problems cause 
this value to decrease. 
09
Power-On Hours 
(POH)
Low
This is how many hours the hard drive has been in a power-on 
state. The raw value lists the total number of hours (or minutes, or 
seconds depending on the manufacturer). 
10
Spin Retry Count  Low
This is the total number of spin start retry attempts. This is the 
number of attempts to spin up to fully operational speed the hard 
drive has made when the first attempt did not succeed. An 
increase in this value is an indicator of hard disk mechanical 
subsystem problems.
11
Recalibration 
Retries 
High
This is the number of times recalibration was requested when the 
first attempt did not succeed. A decrease in this value is an 