9.4 SNMP
Traps
The Prestige will send traps to the SNMP manager when any one of the following events occurs:
Table 9-2 SNMP Traps
TRAP #
TRAP NAME
DESCRIPTION
1
coldStart (defined in RFC-1215)
A trap is sent after booting (power on).
2
warmStart (defined in RFC-1215)
A trap is sent after booting (software reboot).
3
linkUp (defined in RFC-1215)
A trap is sent with the port number.
4
authenticationFailure (defined in
RFC-1215)
RFC-1215)
A trap is sent to the manager when receiving any SNMP
get or set requirements with wrong community (password).
get or set requirements with wrong community (password).
5
whyReboot (defined in ZYXEL-
MIB)
MIB)
A trap is sent with the reason of restart before rebooting
when the system is going to restart (warmstart).
when the system is going to restart (warmstart).
5a
For intentional reboot :
A trap is sent with the message "System reboot by user!" if
reboot is done intentionally, (e.g. download new files, CI
command "sys reboot", etc.).
reboot is done intentionally, (e.g. download new files, CI
command "sys reboot", etc.).
5b
For fatal error :
A trap is sent with the message of the fatal code if the
system reboots because of fatal errors.
system reboots because of fatal errors.
6
linkDown (defined in RFC-1215)
A trap is sent with the port number when any of the links
are down. See the following table.
are down. See the following table.