ZyWALL 5/35/70 Series User’s Guide
673 
Appendix B Hardware Installation
Figure 414    Attaching Rubber Feet    
Note: Do not block the ventilation holes. Leave space between ZyWALLs when 
stacking.
Rack-mounted Installation Requirements
The ZyWALL can be mounted on an EIA standard size, 19-inch rack or in a wiring closet with 
other equipment. Follow the steps below to mount your ZyWALL on a standard EIA rack 
using a rack-mounting kit.  
Note: Make sure the rack will safely support the combined weight of all the equipment 
it contains.
Make sure the position of the ZyWALL does not make the rack unstable or top-
heavy. Take all necessary precautions to anchor the rack securely before 
installing the unit.
Use a #2 Philips screwdriver to install the screws.
Note: Failure to use the proper screws may damage the unit.
Rack-Mounted Installation
Align one bracket with the holes on one side of the ZyWALL and secure it with the 
bracket screws (smaller than the rack-mounting screws).  
Attach the other bracket in a similar fashion.