ZyXEL Communications MES3500-24 User Manual

Page of 349
 Chapter 8 Basic Setting
MES3500-24/24F User’s Guide
87
The following table describes the labels in this screen. 
Table 9   
Basic Setting > System Info 
LABEL
DESCRIPTION
System Name
This field displays the descriptive name of the Switch for identification purposes. 
Product Model  This field displays the model number of the Switch.
ZyNOS F/W 
Version
This field displays the version number of the Switch 's current firmware including the date 
created.
Ethernet 
Address 
This field refers to the Ethernet MAC (Media Access Control) address of the Switch. 
Hardware Monitor   
Temperature 
Unit 
The Switch has temperature sensors that are capable of detecting and reporting if the 
temperature rises above the threshold. You may choose the temperature unit (Centigrade or 
Fahrenheit) in this field. 
Temperature
BOARD, MAC and PHY refer to the location of the temperature sensors on the Switch 
printed circuit board.
Current
This shows the current temperature at this sensor.
MAX
This field displays the maximum temperature measured at this sensor.
MIN
This field displays the minimum temperature measured at this sensor.
Threshold
This field displays the upper temperature limit at this sensor.
Status
This field displays Normal for temperatures below the threshold and Error for those above.
Voltage(V)
The power supply for each voltage has a sensor that is capable of detecting and reporting if 
the voltage falls out of the tolerance range.
Current
This is the current voltage reading.
MAX
This field displays the maximum voltage measured at this point.
MIN
This field displays the minimum voltage measured at this point.
Threshold
This field displays the percentage tolerance of the voltage with which the Switch still works.
Status
Normal indicates that the voltage is within an acceptable operating range at this point; 
otherwise Error is displayed.