ZyXEL Communications ZyWALL 1000 User Manual
Chapter 34 User/Group
ZyWALL USG 1000 User’s Guide
507
Figure 372 User/Group > User > Edit
The following table describes the labels in this screen.
Table 158 User/Group > User > Edit
LABEL
DESCRIPTION
User Name
Type the user name for this user account. You may use 1-31 alphanumeric
characters, underscores(
_
), or dashes (-), but the first character cannot be a
number. This value is case-sensitive. User names have to be different than user
group names, and some words are reserved. See
.
User Type
Select what type of user this is. Choices are:
•
•
Admin - this user can look at and change the configuration of the ZyWALL
•
Limited-Admin - this user can look at the configuration of the ZyWALL but not
to change it
•
User - this user has access to the ZyWALL’s services but cannot look at the
configuration
•
Guest - this user has access to the ZyWALL’s services but cannot look at the
configuration
•
Ext-User - this user account is maintained in a remote server, such as RADIUS
or LDAP. See
Password
This field is not available if you select the Ext-User user type.
Enter the password of this user account. It can consist of 4 - 30 alphanumeric
Enter the password of this user account. It can consist of 4 - 30 alphanumeric
characters.
Retype
This field is not available if you select the Ext-User user type. Enter the password
again.
Description
Enter the description of each user, if any. You can use up to 60 printable ASCII
characters. Default descriptions are provided.
Lease Time
Enter the number of minutes this user has to renew the current session before the
user is logged out. You can specify 1 to 1440 minutes. You can enter 0 to make the
number of minutes unlimited. Admin users renew the session every time the main
screen refreshes in the web configurator. Access users can renew the session by
clicking the Renew button on their screen. If you allow access users to renew time
automatically (see
), the users can select this check box
on their screen as well. In this case, the session is automatically renewed before
the lease time expires.
Reauthentication
Time
Type the number of minutes this user can be logged into the ZyWALL in one
session before the user has to log in again. You can specify 1 to 1440 minutes. You
can enter 0 to make the number of minutes unlimited. Unlike Lease Time, the user
has no opportunity to renew the session without logging out.
OK
Click OK to
save your changes back to the ZyWALL.
Cancel
Click Cancel to exit this screen without saving your changes.