ZyXEL Communications P-335WT User Manual

Page of 485
P-335 Series User’s Guide
Chapter 36 System Information and Diagnosis
358
Figure 217   
IP Frame: ENET0-RECV Size:  44/  44   Time: 17:02:44.262
 Frame Type:
   IP Header:
     IP Version               = 4
     Header Length            = 20
     Type of Service          = 0x00 (0)
     Total Length             = 0x002C (44)
     Identification            = 0x0002 (2)
     Flags                    = 0x00
     Fragment Offset          = 0x00
     Time to Live             = 0xFE (254)
     Protocol                 = 0x06 (TCP)
     Header Checksum          = 0xFB20 (64288)
     Source IP                = 0xC0A80101 (192.168.1.1)
     Destination IP           = 0x00000000 (0.0.0.0)
   TCP Header:
     Source Port              = 0x0401 (1025)
     Destination Port         = 0x000D (13)
     Sequence Number          = 0x05B8D000 (95997952)
     Ack Number               = 0x00000000 (0)
     Header Length            = 24
     Flags                    = 0x02 (....S.)
     Window Size              = 0x2000 (8192)
     Checksum                 = 0xE06A (57450)
     Urgent Ptr               = 0x0000 (0)
     Options                  =
         0000: 02 04 02 00
   RAW DATA:
     0000: 45 00 00 2C 00 02 00 00-FE 06 FB 20 C0 A8 01 01  E......... ....
     0010: 00 00 00 00 04 01 00 0D-05 B8 D0 00 00 00 00 00  ................
     0020: 60 02 20 00 E0 6A 00 00-02 04 02 00              
Press any key to continue...
Call-Triggering Packet Example
36.4  Diagnostic
The diagnostic facility allows you to test the different aspects of your Prestige to determine if 
it is working properly. Menu 24.4 allows you to choose among various types of diagnostic 
tests to evaluate your system, as shown in the following figure.
Follow the procedure next to get to Diagnostic:
From the main menu, type 24 to open Menu 24 – System Maintenance.
From this menu, type 4 to open Menu 24.4 – System Maintenance – Diagnostic.