Anritsu S332D User Manual

Page of 132
Control Byte
#
Name
Description
Watchdog
Timer
A004h
Set T1/E1 Error Insert
Type/Value
Sets the Insertion Error type and the number of errors
Yes
A005h
Set T1/E1 Framing Mode
Sets the Framing Mode of T1/E1 measurement
Yes
A006h
Start and Stop T1/E1
Measurement
Toggles state of T1 and E1 measurements
—-
A007h
Insert Error for T1/E1
Measurement
Inserts the error defined into the data flow
—-
A008h
Get T1/E1 Pattern
Returns the current pattern for T1 and E1 modes
—-
A009h
Get T1/E1 Frame Sync
Status
Returns the current frame sync status for T1 and E1 modes
—-
A00Ah
Get T1/E1 Pattern Sync
Status
Returns the current pattern sync status for T1 and E1 modes
—-
A00Bh
Get T1/E1 Carrier Status
Returns the carrier status for T1 and E1 modes
—-
A00Ch
Get T1/E1 Error Type and
Number
Returns the error type and numbers for T1 and E1 modes
—-
A00Dh
Set T1/E1 Line Coding
Options
Sets line coding options for T1 and E1 modes
Yes
A00Eh
Set E1 Impedance Options
Sets the impedance for the E1 mode
Yes
A00Fh
Read T1 Volts
Peak-to-Peak
Returns the Vpp measurement result
—-
A013h
Set T1/E1 Receive Input
Configuration Options
Sets the Rx input configuration for T1 and E1 modes
Yes
A014h
Set T1/E1 Measurement
Duration
Sets T1 and E1 measurement duration
Yes
A015h
Set T1/E1 Data Logging
Enables/disables data logging in T1/E1 modes
Yes
A016h
Read T1/E1 dBdsx
Initiates a voltage measurement and returns the result in dBdsx
—-
A017h
Read T1/E1 Frequency
Returns the last T1/E1 frequency measurement result in Hz if available
—-
A018h
Read T1/E1 Freq Cal
Returns the current T1/E1 frequency calibration setting
—-
A019h
Set T1/E1 Frequency Cal
Sets the T1/E1 frequency calibration value
Yes
A103h
Select SPA/Power Meter
Signal Standard
Selects a Signal Standard
Yes
A201h
Read External Module
Name
Returns the name of the attached external block converter module (Option 6
only)
—-
A202h
Read External Module
Serial Number
Returns the serial number of the attached external block converter module
(Option 6 only)
—-
A203h
Read External Module
Frequency Range
Returns the frequency range of the attached external block converter module
(Option 6 only)
—-
A204h
Read Module Fail Counter
Returns the value of the module lock fail counter (Option 6 only)
—-
A205h
Clear Module Fail Counter
Sets the module lock fail counter to 0 (Option 6 only)
—-
A104h
Select SPA/Power Meter
Channel
Selects a channel within the range of the currently selected signal standard
Yes
AA30h
Trigger Sweep
Causes the Site Master to perform a sweep if it is in single sweep mode
—-
AA15h
Remote Self Test
Trigger the equivalent of a "key press" selftest.
—-
NOTES: T1/E1 commands are available with Option 50 only. Power Meter commands are available with
Option 29 only.
6
Site Master PM