Anritsu MS2038C User Manual

Page of 24
22
Ordering Information (continued)
Part Number
Frequency  
Range
Waveguide  
Type
Compatible Flanges
1/8 Offset  
Short    
3/8 Offset  
Short      
Precision  
Load
Coaxial to Universal 
Waveguide 
Adapter
[1]
23UM70 
24UM70 
26UM70 
35UM70N
5.85 to 8.20 GHz 
WR137, WG14
CAR70, PAR70, UAR 70, PDR70
23UM84
24UM84
26UM84
35UM84N
7.05 to 10.00 GHz 
WR112, WG15
CBR84, UBR84, PBR84, PDR84
23UM100
24UM100
26UM100
35UM100N
8.20 to 12.40 GHz 
WR90, WG16
CBR100, UBR100, PBR100, PDR100
23UM120 
24UM120 
26UM120 
35UM120N
10.00 to 15.00 GHz 
WR75, WG17
CBR120, UBR120, PBR120, PDR120
23UA187 
24UA187 
26UA187 
35UA187N
3.95 to 5.85 GHz 
WR187, WG12
CPR187F, CPR187G, UG-1352/U, 
UG-1353/U, UG-1728/U, UG-1729/U,
UG-148/U, UG-149A/U
23UA137 
24UA137 
26UA137 
35UA137N
5.85 to 8.20 GHz 
WR137, WG14
CPR137F, CPR137G, UG-1356/U
UG-1357/U, UG-1732/U, UG-1733/U,
UG-343B/U, UG-344/U, UG-440B/U,
UG-441/U
23UA112 
24UA112 
26UA112 
35UA112N
7.05 to 10.00 GHz 
WR112, WG15
CPR112F, CPR112G, UG-1358/U,
UG-1359/U, UG-1734/U, UG-1735/U,
UG-52B/U, UG-51/U, UG-137B/U, UG-138/U
23UA90 
24UA90 
26UA90 
35UA90N
8.20 to 12.40 GHz 
WR90, WG16
CPR90F, CPR90G, UG-1360/U,
UG-1361/U, UG-1736/U, UG-1737/U,
UG-40B/U, UG-39/U, UG-135/U,
UG-136B/U
23UA62 
24UA62 
26UA62 
35UA62N
12.40 to 18.00 GHz 
WR62, WG18
UG-541A/U, UG-419/U, UG-1665/U, 
UG1666/U
23UA42 
24UA42 
26UA42 
35UA42K
17.00 to 26.50 GHz 
WR42, WG20
UG-596A/U, UG-595/U, UG-597/U
UG-598A/U
[1] For Coaxial/Waveguide Adapter part numbers, N designates Type N and K designates K-Connector
Waveguide Calibration Components and WG/
Coaxial Adapters
Recommended waveguide calibration procedure requires 
two offset shorts and a precise load. The waveguide/coax 
adapter, shown attached to test port #2, adapts the VNA 
Master test ports to the waveguide under test.
Manuals
10580-00305  
VNA Master User’s Guide     
10580-00306  
VNA Master Programming Manual      
10580-00289        VNA Measurement Guide
10580-00244          Spectrum Analyzer Measurement Guide
10580-00240          Power Meter Measurement Guide
10580-00215          ODTF-1 Optical Distance-to-Fault Module –  
Quick Start Guide
Related Literature, Application Notes
11410-00206  
Time Domain for Vector Network Analyzers
11410-00214  
Reflectometer Measurements – Revisited
11410-00270  
What is Your Measurement Accuracy?
11410-00373  
Distance-to-Fault
11410-00387  
Primer on Vector Network Analysis
11410-00414  
High Accuracy Power Meter, PSN50
11410-00424  
USB Power Sensor MA24106A
11410-00483  
Inline High Power Sensor MA24104A
11410-00504  
Microwave USB Power Sensor MA241x8A
11410-00531  
Practical Tips on Making “Vector Voltmeter (VVM)”
 
Phase Measurements using VNA Master (Opt. 15)
11410-00472 
Measuring Interference