NEC IP8800/S6300 User Manual

Page of 250
2.   
Troubleshooting System Failures
17
2.2.2
Isolating Failures on External Power Unit
If the external power unit fails, follow the steps below to isolate the failure.
Table 2-5: Isolating Failures on External Power Unit
Table 2-6: Isolating Failures on External Power Unit (Main Body)
Table 2-7: Isolating Failures on Power Module
No.
Failure
Action
1
POWER LED on the external power unit is lit in 
green
Check LED on the power module mounted on the external power unit 
and identify the power module that is not normally running. If the power 
module is normally running, the states below are provided.
• EPU-A:
DC-OK: Lit in green, DC-ALM: OFF
• EPU-B:
DC-OK: Lit in green, DC-FAIL: OFF, AC-OK: Lit in green
For the power module that is not normally running, implement "
2
POWER LED on the external power unit is OFF
Follow the steps in "
."
No.
Failure
Action
1
Power switch on the external power unit is OFF
Turn on the power switch.
2
Power cable of the external power unit is not 
correctly connected to the system
1. Turn off the power switch.
2. Connect the power cable correctly.
3. Turn on the power switch.
3
Input power to the external power unit is out of the 
range below
(AC power supply: 90 to 132V)
Ask the system administrator to take the action because of the failure on 
the power supply facility (i.e. not the failure on this system).
4
Other than 1 to 3 above
Replace the external power unit.
No.
Failure
Action
1
Power switch on the power module is OFF
Turn on the power switch on the power module.
2
Power cable of the power module is not correctly 
connected to the system
1. Turn off the power switch on the power module.
2. Connect the power cable correctly.
3. Turn on the power switch on the power module.
3
Power module is not correctly mounted on the 
external power unit
1. Turn off the power switch.
2. Mount the power module correctly.
3. Turn on the power switch.
4
Other than 1 to 3 above
Replace the power module.