NEC IP8800/S2400 User Manual

Page of 250
3.   
Troubleshooting Functional Failures in Operation
27
3.4
Network Interface Communication Failure
3.4.1
Ethernet Port Cannot Be Connected
If the Ethernet port has possibly caused the communication failure, check for the NIF [IP8800/S6700] [IP8800/
S6600] [IP8800/S6300] 
and port statuses as follows.
(1) Checking NIF status [IP8800/S6700] [IP8800/S6600] [IP8800/S6300]
1. Checking log
For the log, see the manual "Message Log Reference."
2. Isolating the problem according to the NIF status.
Check the NIF status by using the show interfaces command, and isolate the problem according to the table 
below.
Table 3-6: Check and Action for NIF Status
(2) Checking port status
1. Checking log
For the log, see the manual "Message Log Reference."
2. Isolating the problem according to the port status.
Check the port status by using the show interfaces command, and isolate the problem according to the table 
below.
No.
NIF Status
Problem
Action
1
active
The NIF is operating normally.
Check the port status according to "
."
2
notconnect
The NIF is not installed.
Install the NIF board.
3
inactive
The inactivate command is set.
Use the activate command to activate the NIF.
The NIF is not fully inserted.
Install the NIF board correctly.
NIF is not activated.
Use the show system command to check the BSU operation status 
and set the operation status to "active." [IP8800/S6700]
Use the show system command to check the PSP operation status and 
set the operation status to "active." [IP8800/S6600] [IP8800/S6300]
NIF not supported by the software 
version is installed.
Check the NIF board type and software version. Replace the NIF board 
or update the software.
NIF not supported by this system is 
installed.
Replace the NIF board.
4
fault
The NIF is faulty.
According to the log of the NIF displayed by the show logging 
command, see the corresponding part in the manual "Message Log 
Reference" and follow the descriptions in [Action].
5
initialize
The NIF is being initialized.
Wait until initialization completes.
6
disable
no power enable is set by 
configuration command.
Confirm that the NIF board to be used is installed and enter 
configuration command power enable to activate the NIF.