NEC 151944 User Manual
ND-46550
(E)
CHAPTER
3
Page 65
Revision 2.0
2.3.2 DTI Connection at Remote Site
Connect the cable to a CSU or directly to the Main PIM via the CN connector on the DAIB/DAIC card as shown
in
in
. Connection of DAIC cards between the Main PIM and the Remote PIM is available in the same
manner as the DAIA-DAIB connection.
Figure 3-40 DTI Cable Connection via CN Connector (Remote Site)
REMOTE PIM
CSU
MDF
TWISTED-PAIR
CABLE
CABLE
DAIB/
BWB
(SHIELD TYPE)
MAX. 656 ft. (200 m)
CN
DAIB/DAIC
MDF
CN
TB
TA
RB
RA
RA
TO CSU/MAIN PIM
SEND
RECEIVE
4
3
2
1
1
BA1
AA1
BA0
AA0
AA0
TB
TA
RB
RA
CN CONNECTOR
(0.65
Φ
cable)
Note:
When the Remote PIM is directly connected without CSU, maximum distance is
1312 ft. (400 m) between the Main PIM and the Remote PIM.
1312 ft. (400 m) between the Main PIM and the Remote PIM.
Note
DAIC