Motorola 557925-001-00 User Manual

Page of 12
 
 
Location 
RSSI Loss Note 
Transmitter 
-28dBm 
42dB 
Antenna to air conversion loss.  Measured at 1m 
using integrated Intel Pro2200B/G in Dell Laptop. 
-32dBm 
4dB 
Same room, with AP mounted 12” from floor 
-60dBm 
32dB 
Down one floor 
-55dBm 
27dB 
One room over 
-83dBm 
55dB 
Across the hall, over one room 
-80dBm 
52dB 
Two rooms over 
 
Note some interesting results: 
 
1.  We can predict the measured RSSI three rooms over would be -105dBm, well below the 
carrier detect range. 
2.  RSSI loss is approximately 25dB per room/wall.  Vertical loss is 32dB. 
Based on the RSSI loss from A to B, this installation would require one WallPlate for every four 
rooms. 
Motorola, Inc 
 
Page 6 of 12