Commissioning (software) 
 
4.4 Creating an axis 
 
D410 
80
 
Commissioning Manual, 08/2008 Edition 
5.  Select the drive to be aligned (SINAMICS Integrated) in this dialog box and then click 
"Align". 
The addresses are assigned to the configured components and entered in HW Config. 
 
 
 
Note 
This device alignment is only necessary if not already done in the course of drive 
commissioning. This shows that no interconnectable drive of the SINAMICS Integrated 
type is displayed. 
 
 
Figure 4-17  Assigning a drive 
6.  Select a drive unit in the "Drive Assignment" dialog box. Normally only a SINAMICS 
Integrated drive will be offered. Exception: A D410 has been configured, for example, 
with a hydraulic axis. You have already defined the message frame type in the previous 
steps and so only need to accept it. To do this, click the "Accept data from the drive" 
button to transfer the SINAMICS Integrated values in the axis wizards. 
7.  Select the encoder from the "Encoder Assignment" dialog box and then adapt its 
properties. Click the "Accept data from the drive" button to transfer the SINAMICS 
Integrated values in the axis wizards. 
 
 
 
Note 
For motors with DRIVE-CLiQ interface, a "Accept data from the drive" automatically 
transfers the determined drive and encoder data (e.g. encoder type). This requires that 
the data has already been fetched from the attached devices. Namely, an offline 
configuration has already been used to establish an online connection or an online 
configuration has been performed. 
8.  Complete the Axis Wizard session. 
The configured axis is displayed in the Project Navigator. After having downloaded it to the 
target system, you can test the axis using the axis or drive control panel.