Chapter 3: Configuration
• Timer Values: To set the GARP join timer, leave timer, and leave all timers, the unit is microseconds (ms).
  Three different timers can be configured on this page:
  - Join Timer: The default value for Join timer is 200 ms.
  - Leave Timer: The range of values for Leave Time is 600–1000 ms. The default value for Leave Timer is 600 ms.
  - Leave All Timer: The default value for Leave All Timer is 10000 ms.
• Application: Currently only supported application is GVRP.
• Attribute Type: Currently only supported Attribute Type is VLAN.
• GARP Applicant: This configuration is used to configure the Applicant state machine behavior for GARP on a particular port 
locally.
  - normal-participant: In this mode the Applicant state machine will operate normally in GARP protocol exchanges.
  - non-participant: In this mode the Applicant state machine will not participate in the protocol operation.
  The default configuration is normal participant.
• Buttons:
  - Save: Click to save changes.
  - Reset: Click to undo any changes made locally and revert to previously saved values