Panasonic PT-DW730EL User Manual

Page of 108
Technical Information
ENGLISH - 95
Appendix
PJLink protocol
The network function of this projector supports the PJLink class 1, and the PJLink protocol can be used to 
perform projector setting and projector status query operations from a computer. 
 
Control commands
The following table lists the PJLink protocol commands that can be used to control the projector. 
Command
Control details
Notes
POWR
Power supply control
Parameters
0 = Standby
1 = Power ON
POWR?
Power supply status query
Parameters
0 = Standby 
1 = Power ON
2 = Cool-down in progress 
3 = Warm-up in progress
INPT
Input selection
Parameters
11=RGB1 
12=RGB2 
21=VIDEO
22=S-VIDEO  31=DVI-D
INPT?
Input selection query
AVMT
Shutter control
Parameters
30 = SHUTTER function off (picture mute canceled)
31 = SHUTTER function on (picture mute)
AVMT?
Shutter status query
ERST?
Error status query
Parameters
1st byte: Indicates fan errors, range 0 - 2
2nd byte: Indicates lamp errors, range 0 - 2
3rd byte: Indicates temperature errors, range 0 - 2
4th byte: Indicates cover open errors, range 0 - 2
5th byte: Indicates filter errors, range 0 - 2
6th byte: Indicates other errors, range 0 - 2
Definitions for each value from 0 to 2 are as follows
0 = No error detected   1 = Warning   2 = Error 
LAMP?
Lamp status query
Parameters
1st digits (1 - 5 digits): Lamp 1 cumulative operating time
2nd digit: 0 = Lamp 1 off, 1 = Lamp 1 on
3rd digits (1 - 5 digits): Lamp 2 cumulative operating time
4th digit: 0 = Lamp 2 off, 1 = Lamp 2 on
INST?
Input selection list query
Parameters are returned with the following values. 
“11 12 21 22 31”
NAME?
Projector name query
Returns the name set in [PROJECTOR NAME] of [NETWORK 
SETUP]. 
INF1?
Manufacturer name query Returns “Panasonic”. 
INF2?
Model name query
Returns “DX800E” “DW730E”. 
INF0?
Other information query
Returns information such as version number. 
CLSS?
Class information query
Returns “1”. 
 
PJLink security authentication
The password used for PJLink is the same as that of the password set for web browser control. 
When using PJLink without security authentication, do not set a password for web browser control. 
 
z
For specifications regarding PJLink, refer to the Japan Business Machine and Information System 
Industries Association website. 
URL http://pjlink.jbmia.or.jp/english/
Technical Information