Shutter Lock 
The shutter lock is used to fix the shutters in position 
after they have been focused. To lock, slide the lever 
to the closed position. To unlock, slide the lever to the 
unlocked position. 
 
 
Rotatable Shutters 
The shutter and reflector assembly can be rotated 
to position the shutters for the best cut, or to move 
the focus knobs into an optimum operating 
position. 
1.  Check that the front accessory cover is closed, 
securing the colour frame. Ensure any pattern 
holders or iris/ accessories  are secured in the 
accessory slots (refer above) 
2.  Loosen the top shutter and reflector assembly screw clamp 
3.  Rotate the shutter and reflector assembly to the required position 
4.  Tighten the shutter and reflector assembly screw clamp. 
 
Accessory Mounting Positions 
 
The SPX range provides good image projection right across the beam. 
NOTE: The SPX range has two different pattern holders.  
SPXGHB 
For 'B' size steel patterns 
SPXGHGB 
For “B” size glass patterns  
 
The SPX provides for mounting 2 pattern holders. 
The front accessory slot will house: 
 
Glass pattern holder (code SPXGHB) 
 
An adjustable iris (code 20IRIS) 
 
A motorised gobo rotator (e.g. Rosco/Apollo) 
The rear slot will house a Philips Selecon steel pattern holder  
(order code: SPXGHB). 
Refer to website for a list of compatible third party accessories. 
To fit an accessory in the front slot 
Slide the accessory slot cover forward to reveal the aperture. Slide the 
accessory into the front slot. Slide the slot cover back into place to lock 
in the accessory. Follow the instructions of the accessory manufacturer 
in regards to operating and safety procedures. 
To fit an accessory in the rear slot 
Slide the accessory slot cover forward to reveal the aperture. Slide the 
pattern holder into the rear slot. Slide the slot cover back into place to 
lock in the pattern holder. 
To insert an Iris 
To mount the Iris (20IRIS) slide the accessory slot cover forward to 
reveal the aperture. Slide the iris into the front slot and push to the 
bottom of the slot. Slide the slot cover back into place to lock in the iris.  
NB: Do not operate and adjustable iris in a ½ closed to fully closed position for extended periods of 
time as the heat may damage to iris leaves.