Runco LS-HB User Manual

Page of 112
Runco LS-HB/LS-HB Ultra Installation/Operation Manual
73 
PRE
L
IMINAR
Y
5.1 
Lamp Replacement
The lamp should be replaced when it reaches the end of its life (typically 2000 hours), or 
sooner if a noticeable degradation in brightness occurs. Contact your Runco dealer to 
obtain a replacement lamp.
1.
Turn off the projector and unplug the power cord. Allow the projector to cool 
down for approximately 60 minutes prior to removing the lamp assembly for 
replacement. 
2.
Using a flat-blade screwdriver, loosen 
the two screws holding the rear 
compartment cover in place.
3.
Remove the rear compartment cover 
by tilting it upward. 
4.
Loosen the screw on the lamp cover 
and pull the lamp cover out.
5.
Loosen the two screws on the lamp 
module.
6.
Pull the lamp module handle firmly to 
remove the lamp module. 
7.
Perform Steps 6 through 2 (in reverse 
order) to install the new lamp module. 
8.
Turn on the power and reset the lamp 
timer. 