Texas Instruments DH91x User Manual

Page of 77
— 68 — 
Command Group 03 
ASCII 
HEX 
Function 
Description 
Return 
Value 
1:Normal 
2:Dynamic Eco 
VXXS0319n 56h Xh Xh 53h 30h 33h 31h 39h nh 0Dh  Set Lamp Mode 
0:Eco 
1:Normal 
2:Dynamic Eco 
P/F 
VXXG0321  56h xh xh 47h 30h 33h 32h 31h 0Dh 
Get Splash Logo 
0:On 
1:Off 
Pn/F 
VXXS0321n 56h xh xh 53h 30h 33h 32h 31h nh 0Dh  Set Splash Logo 
0:On 
1:Off 
P/F 
VXXG0322  56h xh xh 47h 30h 33h 32h 32h 0Dh 
Get Fan Speed 
0:Normal 
1:High 
Pn/F 
VXXS0322n 56h xh xh 53h 30h 33h 32h 32h nh 0Dh  Set Fan Speed 
0:Normal 
1:High 
P/F 
VXXG0358  56h xh xh 47h 30h 33h 35h 38h 0Dh 
Get IR On/Off 
Control 
0:Both IR turn on 
1:Front IR turn on 
2:Back IR turn on 
3:Both IR turn off 
Pn/F 
VXXS0358n 56h xh xh 53h 30h 33h 35h 38h nh 0Dh 
Set IR On/Off 
Control 
0:Both IR turn on 
1:Front IR turn on 
2:Back IR turn on 
3:Both IR turn off 
P/F