Sony VPL-HS1 User Manual

Page of 152
39
 GB
Replacing the Air Filter
Ot
her
s
Notes
• Do not put your hands into the lamp replacement spot, or not 
fall any liquid or object into it to avoid electrical shock or fire.
• Be sure to use the LMP-H120  Projector Lamp for replacement. 
If you use lamps other than LMP-H120, the projector may 
cause a malfunction.
• Be sure to turn off the projector and unplug the power cord 
before replacing the lamp.
Disposal of used projector lamp
As the materials used in this lamp are similar to those 
of a fluorescent lamp, you should dispose of a used 
projector lamp in the same way as a fluorescent lamp.
Replacing the Air 
Filter
The air filter should be replaced periodically. When 
“Please replace the filter.” appears on the screen, 
replace the air filter immediately. 
Notes
• Replacing the air filter is very important to maintain the high 
efficiency of the projector and to prevent a malfunction. When 
the replacement message appears on the screen, replace the air 
filter without delay.
• When removing the air filter from the projector, be careful that 
no dust or object gets into the inside of the projector.
1 Place a protective sheet (cloth) beneath 
the projector. Turn the projector over so 
you can see its underside.
Note
Be sure that the projector is stable after turning it over.
2 Slide the release lever on the adjuster 
outward and turn the adjuster clockwise to 
remove the adjuster.
3 Push the knob on the filter cover to 
remove the filter cover.
4 Remove the filter holder.
5 Remove the air filter from the filter holder 
by holding the tab on the air filter.
6 Insert the new air filter into the filter holder 
with the white surface up, then replace it in 
the projector.
7 Replace the filter cover.
8 Attach the adjuster.
2
1
3
Release lever
Knob
Air filter
Filter holder
Tab