Sony RM-PJM10 User Manual

Page of 118
3-7
VPL-CS2/CX1
3-5. White Balance Adjustment on
Servicing
3-5-1. Signal Level Adjustment
1.
Input the 10 STEP signal to INPUT-A.
2.
Warm up the unit at least 10 minutes. Enter the V-
AMP/BRT adjustment mode from the Service mode
as follows :
Service Mode 
→ 
MENU 
→ 
DEV.
 
ADJ 
 P. DRV
 VAMP/BRT.
3.
Measure TP813, TP817, and TP821 on the C board
by osciloscope. Adujust V AMP/BRT so that the
minimum value in all black level is 2.8 V.
4.
Input the 95 IRE and 100 IRE STEP signals.
5.
Set the unit in G-only mode.
6.
Enter the P.DRV on the MENU screen by the DEV.
ADJ.
7.
Discriminate the 95 IRE and 100 IRE by the V-
AMP/CONT controls of the P.DRV.
8.
Set the unit in R-only mode.
9.
Discriminate the 95 IRE and 100 IRE by the V-
AMP/SUB CONT R controls of the P.DRV.
10. Set the unit in B-only mode.
11. Discriminate the 95 IRE and 100 IRE by the V-
AMP/SUB CONT B controls of the P.DRV.
3-5-2. White Balance Adjustment
1) HIGH Mode of INPUT-A
Input the 10 STEP signal to INPUT-A, and observe the
chromaticity of each luminance.
When varying the chromaticity of each luminance,
perform the following adjustments.
1.
Input the 100 IRE FLAT FIELD signal to INPUT-A.
2.
Measure the chromaticity (x, y).
3.
Input the 50 IRE FLAT FIELD signal to INPUT-A.
4.
Adjust the chromaticity (x, y) to the values measured
in step 2 by the VAMP/SUB CONT R and B of the
P. DRV.
2) LOW Mode of INPUT-A
1.
Input the 80 IRE FLAT FIELD signal to INPUT-A.
2.
Set the GAIN G to 60 with the LOW mode of the W/B.
3.
Measure the chromaticity (x, y).
4.
Input the 25 IRE FLAT FIELD signal to INPUT-A.
5.
Adjust the chromaticity (x, y) to the values measured in
step 3 by the BIAS G and B of the LOW mode of the W/B.
6.
Repeat above steps 1 to 5 until the chromaticity become
the following values.
±
 0.002, y 
±
 0.003 (The x and y are the values
measured in step 3.)
3) HIGH Mode of VIDEO
Switch the input to COMPONENT from INPUT-A by the
SET SETTING of the Menu screen.
Input the 15k COMPONENT 10 STEP signal to INPUT-A,
and observe the chromaticity of each luminance.
When varying the chromaticity of each luminance, perform
the following adjustments.
1.
Input the 100 IRE FLAT FIELD signal to INPUT-A.
2.
Measure the chromaticity (x, y).
3.
Input the 50 IRE FLAT FIELD signal to INPUT-A.
4.
Adjust the chromaticity (x, y) to the values measured in
step 2 by the VAMP/SUB CONT R and B of the P. DRV.
4) LOW Mode of VIDEO
1.
Input the 80 IRE 15k COMPONENT FLAT FIELD
signal to INPUT-A.
2.
Set the GAIN G to 60 with the LOW mode of the W/B.
3.
Measure the chromaticity (x, y).
4.
Input the 25 IRE FLAT FIELD signal to INPUT-A.
5.
Adjust the chromaticity (x, y) to the values measured in
step 3 by the BIAS G and B of the LOW mode of the W/B.
6.
Repeat above steps 1 to 5 until the chromaticity become
the following values.
±
 0.002, y 
±
 0.003 (The x and y are the values
measured in step 3.)