CHAPTER 5: RMS REMOTE MONITORING SYSTEM
The Acheron Designer is optionally available with the RMS 
remote monitoring system module, allowing it to be con-
nected to an RMS network. RMS allows real-time monitor-
ing of multiple Meyer Sound self-powered loudspeakers 
from a Windows-based computer. The RMS host computer 
communicates with Meyer Sound loudspeakers (equipped 
with RMS modules) via a simple twisted pair network, or an 
Ethernet network using an FT-10 to Ethernet adapter.
NOTE: 
For the latest RMS system require-
ments, visit 
.
NOTE: 
The RMS software allows you to dis-
able Mute and Solo functions to eliminate any 
possibility of accidentally muting loudspeakers. Mute 
and solo capability can also be disabled by removing 
the Mute Jumper from RMS modules. For more infor-
mation, refer to the RMS User Guide.
NOTE: 
RMS does not control AC power.
RMS SOFTWARE
The optional RMS software provides extensive system sta-
tus and performance data for each loudspeaker, including 
amplifier voltage, limiting activity, power output, driver sta-
tus, as well as mute and solo capability. Loudspeakers are 
added to the RMS network and assigned a node name dur-
ing a one-time commissioning procedure where the loud-
speaker is identified by either entering its unique Neuron ID, 
or by pressing its Identify button.
Once loudspeakers are identified on the RMS network, they 
appear in the RMS software as icons and views; they are 
also automatically added to the RMS database on the host 
computer.
RMS Add Loudspeaker Dialog Box
Acheron Designer RMS Icons