Sony VPL-FX51 User Manual

Page of 34
24
VPL-PX35/PX40/FX51
<Table 1>
<Table 2>
Item Number
Data
Remarks
Item
Upper byte
Lower byte
Data
Upper byte
Lower byte
STATUS ERROR
01h
01h
NO ERROR
00h
00h
Get only
LAMP ERROR
00h
01h
FAN ERROR
00h
02h
COVER ERROR
00h
04h
TEMP ERROR
00h
08h
D5V ERROR
00h
10h
POWER ERROR
00h
20h
WARNING ERROR
00h
40h
STATUS POWER
01h
02h
STANBY
00h
00h
START UP
00h
01h
STARTUP LAMP
00h
02h
POWER ON
00h
03h
COOLING1
00h
04h
COOLING2
00h
05h
SAVING COOLING1
00h
06h
SAVING COOLING2
00h
07h
SAVING STABY
00h
08h
CONTROL MODE SEL
01h
05h
USER MODE
00h
00h
SERVICE MODE
00h
01h
LAMP TIMER
01h
13h
LAMP USE TIME
0000h-ffffh
*
1
ROM VERSION
01h
1Dh
MAIN ROM VERSION
*
2
SC ROM VERSION
01h
1Eh
SC ROM VERSION
*
2
STATUS SECURITY
*
3
01h
1Fh
Disable
00h
00h
Enable
00h
01h
Channel Memory Reset
03h
01h
_
00h
00h
Set only
Status Memory Reset
02h
Set Memory Reset
03h
W/B All Save
04h
W/B Low Save
05h
W/B High Save
06h
Sircs (15 bit category)
17h
Refer to table 6
_
00h
00h
Set only
*
4
Sircs (20 bit category)
19h
Refer to table 7
_
00h
00h
(VPL-PX35, PX40)
            <Table 3>
Item Number
Data
Item
Data
Upper byte
Lower byte
ACK
_
00h
00h
NAK
Undefined Command
01h
01h
Size Error
04h
Select Error
05h
Range Over
06h
Not Applicable
0Ah
Check Sum Error
F0h
10h
Framing Error
20h
Parity Error
30h
Over Rub Error
40h
Other Comm Error
50h
(VPL-PX35, PX40)
Approximate Return Waiting Times
The await-return time is approx. 50 msec.
n
This is the case, unless the communica-
tions are interfered anyway.
*
1 Example) In case the lamp timer indicates
1000H, return values are [03h] upper byte and
[E8h] lower byte.
*
2 Example) In case the software version is 1.03,
return values are [01h] upper byte and [03h]
lower byte.
*
3 While the set is security locked, after power
switch is turned on, you can check that pass
sword input screen is indicated or not.
During pass word input screen indicating, return
values are [00h] upper byte and [01h] lower
byte.
*
4 It is corresponded to single command only.