Allied Telesis AT-FS238B/1 Data Sheet
Status Indicators
System LEDs
Power
Indicates power is applied to the
converter
converter
Per fiber port:
Link
Indicates a valid receive link exists
Duplex
Indicates full or half-duplex operation
Collision
Indicates collision during packet
Per copper port:
Link
Indicates a valid receive link exists
Speed
Indicates either 10Mbps or 100Mbps
operation
operation
Auto
Indicates port is set for auto-
negotiation
negotiation
FD/Collision
Indicates collision during packet
transmission on the port
Indicates full or half-duplex operation
transmission on the port
Indicates full or half-duplex operation
Operational Characterisitcs
Per fiber port:
Duplex
Selects either full or half-duplex
operation
operation
Per copper port:
Auto
Selects auto-negotiation mode or
manual setting
manual setting
Duplex
Forces port to full or half-duplex
operation
(Auto-setting = manual only)
operation
(Auto-setting = manual only)
Speed
Forces port to 10Mbps or 100Mbps
operation
(Auto-setting = manual only)
operation
(Auto-setting = manual only)
Operational Mode
MissingLink (ML)
Smart MissingLink (SML)
Link Test
Smart MissingLink (SML)
Link Test
Packet buffer
28k per port
MAC address table
8k addresses
Forwarding/filtering rate 148,880pps for 100Mbps
14,880pps for 10Mbps
Latency 14.3µsec
(64 byte packet, 100Mbps
full-duplex)
full-duplex)
Power Characteristics
Input supply voltage
12vDC or 12-50vDC
Rated currents
.5A max.
Power consumption 24W
max.
Physical Characteristics
Dimensions
10.5cm x 9.5cm x 2.5cm
(4.12" x 3.75" x 1")
(4.12" x 3.75" x 1")
Weight
294g (10.4 oz)
Fiber Optic Port Specifications
Fiber Optic Transmitter
Fiber Optic Receiver
Fiber Optic Datalink
Fiber Optic Loss Specification (Benchmark)
Environmental Specifications
Operating temp.
0°C to 40°C (32°F to 104°F)
Storage temp.
-20°C to 70°C (-13°F to 158°F)
Relative humidity
5% to 90% non-condensing
(operating)
Relative humidity
5% to 95% non-condensing
(storage)
Operating and
Up to 3,048m (10,000 feet)
storage altitude
Electrical/Mechanical Approvals
CE
IEEE 802.3, IEEE 802.3u
Safety
UL60950 (cULus), EN60950,
EN60825 (TUV)
EN60825 (TUV)
Emission
FCC Part 15 Class B, EN55022 Class B
Immunity
EN55024
AT-FS238
| 2 Port Fast Ethernet Single Strand Speed/Media Converting Switch
USA Headquarters
|
19800 North Creek Parkway
|
Suite 200
|
Bothell
|
WA 98011
|
USA
|
T: +1 800 424 4284
|
F: +1 425 481 3895
European Headquarters
|
Via Motta 24
|
6830 Chiasso
|
Switzerland
|
T: +41 91 69769.00
|
F: +41 91 69769.11
Asia-Pacific Headquarters
|
11 Tai Seng Link
|
Singapore
|
534182
|
T: +65 6383 3832
|
F: +65 6383 3830
www.alliedtelesis.com
© 2007 Allied Telesis Inc. All rights reserved. Information in this document is subject to change without notice. All company names, logos, and product designs that are trademarks or registered trademarks are the property of their respective owners.
617-00520 Rev E
Ordering Information
AT-FS238A/1-10
2 port single strand fiber media converter, 10/100TX
(RJ-45) to 100FX (SC) (1310nm TX/1550nm RX) with
12vDC power supply and distances up to 15km
(RJ-45) to 100FX (SC) (1310nm TX/1550nm RX) with
12vDC power supply and distances up to 15km
AT-FS238A/2-10
2 port single strand fiber media converter, 10/100TX
(RJ-45) to 100FX (SC) (1310nm TX/1550nm RX) with
12vDC power supply and distances up to 40km
(RJ-45) to 100FX (SC) (1310nm TX/1550nm RX) with
12vDC power supply and distances up to 40km
AT-FS238B/1-10
2 port single strand fiber media converter, 10/100TX
(RJ-45) to 100FX (SC) (1550nm TX/1310nm RX) with
12vDC power supply and distances up to 15km
(RJ-45) to 100FX (SC) (1550nm TX/1310nm RX) with
12vDC power supply and distances up to 15km
AT-FS238B/2-10
2 port single strand fiber media converter, 10/100TX
(RJ-45) to 100FX (SC) (1550nm TX/1310nm RX) with
12vDC power supply and distances up to 40km
(RJ-45) to 100FX (SC) (1550nm TX/1310nm RX) with
12vDC power supply and distances up to 40km
Associated Products
AT-PWR237-11
12vDC power supply with screw terminals
Model
Fiber Type
1
Fiber Optic
Diameter
(Microns)
Diameter
(Microns)
Optical
Wavelength
Wavelength
Launch Power (dBm)
2
Min.
Avg.
2
Max.
AT-FS238a/1
SMF (SC)
9/125
1310nm
-15.0
-11.0
-8.0
AT-FS238a/2
SMF (SC)
9/125
1310nm
-8.0
-5.0
-2.0
AT-FS238b/1
SMF (SC)
9/125
1550nm
-15.0
-11.0
-8.0
AT-FS238b/2
SMF (SC)
9/125
1550nm
-8.0
-5.0
-2.0
1 SMF = Single-mode fiber
2 Launch power is
2 Launch power is
measured at one meter
from the transmitter
from the transmitter
3 Launch power (Avg.) is
power coupled into a
single-mode fiber
single-mode fiber
Model
Fiber Type
1
Fiber Optic
Diameter
(Microns)
Diameter
(Microns)
Optical
Wavelength
Wavelength
Receiver Sensitivity (dBm)
Max.
Avg.
Saturation
AT-FS238a/1
SMF (SC)
9/125
1550nm
-30.0
n/a
-7.5
AT-FS238a/2
SMF (SC)
9/125
1550nm
-33.0
n/a
-2.0
AT-FS238b/1
SMF (SC)
9/125
1310nm
-30.0
n/a
-7.5
AT-FS238b/2
SMF (SC)
9/125
1310nm
-33.0
n/a
-2.0
1 SMF = Single-mode fiber
Model
Fiber Type
1
Minimum
Power/Link
Budget
Power/Link
Budget
Minimum
Operating
Distance
Operating
Distance
2
Minimum
Operating
Distance
Operating
Distance
3
AT-FS238a/1
9/125 SMF
6.0dB
0
15km (9.4mi)
AT-FS238a/2
9/125 SMF
16.0dB
0
40km (9.4mi)
AT-FS238b/1
9/125 SMF
6.0dB
0
15km (9.4mi)
AT-FS238b/2
9/125 SMF
16.0dB
0
40km (9.4mi)
1 SMF = Single-mode fiber
2 The recommended mimimum range is
2 The recommended mimimum range is
stated in all cases where the maximum
transmitter output power exceeds the
receiver’s saturation level. This is to
prevent blinding or burning out of the
optical receiver on the far-end mode.
transmitter output power exceeds the
receiver’s saturation level. This is to
prevent blinding or burning out of the
optical receiver on the far-end mode.
3. Distance is calculated based on ideal
situations without any other loss factor
Fiber Type
1
Fiber Optic
Diameter
(Microns)
Diameter
(Microns)
Optical
Wavelength
Wavelength
Typical
Loss
Factor
Loss
Factor
Bandwidth
SMF (SC)
9/125
1310nm 0.4dBm
n/a