Warning display
You are informed of the contents of warning notices by the (repeated) displays of the [WARNING] and 
[LAMP] indicators. Moreover, the [STAND BY / ON] indicator, which shows the operating mode of the unit, 
is displayed simultaneously as described above.
Upon activation of the warning mode, the projection is interrupted at the same time for about 60 seconds 
and the cooling fan is turned on. Please disconnect the power plug from the electric socket after the 
cooling fan has stopped. Subsequently, please perform the following checks and take appropriate 
countermeasures.
Lighting/flashing lights 
status diagram
Blinking
Frequency
Content
Confirmation and 
countermeasures
   
                 
(red) 
1 times
Abnormalities in the power 
supply
  Check that nothing is 
blocking the air inlets.
  Check that the external 
temperature is normal.
Action
Leave the unit until it cools 
down.
After that, turn on the power 
again.
2 times
Cooling fan stops
3 times
Internal temperature is too 
high
4 times
External temperature is 
too high
 
    
(orange)  (red)  
Simultaneous 
flashing 
1 times
Abnormal electrical circuit
2 times
3 times
4 times
If something is wrong with 
the automatic lens cover
  Check that an impact shock 
has not occurred during 
operation.
  Check that the lamp 
unit and lamp cover are 
correctly installed.
  Check that nothing is 
blocking the auto lens 
cover.
Action
Turn on the power again.
1 times
Lamp does not light up 
and unit is unable to 
project
2 times
Lamp is turned off during 
projection
3 times
Lamp cover is removed
Controls and features (continued)
Main body - Warning display and confirmation/response
STANDBY/ON
LAMP
WARNING
STANDBY/ON
LAMP
WARNING
STANDBY/ON
LAMP
WARNING
 (orange)   (red)
Mode 
display
Mode 
display
Mode 
display
If the warning indication is displayed again, please wait for the cooling fan stopped, then pull out the power 
plug from the power outlet.  Then call your authorized dealer for repair.
(*) If the scheduled time for the replacement of the lamp is exceeded, the light might light up.
(*)