Kodak KKA User Manual
SERVICE MANUAL
14
30APR96 – SM4530-1
Installing the MECHANISM ASSEMBLY
Important
To insert the SELECT BUTTON into the hole in the SELECT LEVER when installing the MECHANISM ASSEMBLY,
hold the SELECT BUTTON completely down.
hold the SELECT BUTTON completely down.
[1] Do the removal procedure for the MECHANISM ASSEMBLY in reverse order.
Replacing the AUTO-FOCUS BRACKET ASSEMBLY
Warning
Dangerous Voltage
[1] Disconnect the main power.
[2] Do the replacement procedure for the LOWER HOUSING ASSEMBLY.
[3] Cut and remove the necessary WIRE TIES.
[4] Disconnect the 2 wires from the CYCLE SOLENOID on the SMALL CIRCUIT BOARD.
[5] Pull the SMALL CIRCUIT BOARD up.
[6] Do the replacement procedure for the MECHANISM ASSEMBLY.
[7] Remove the
Torx SCREW (on N.P. models) (or Hex SCREW on Painted Models) from the WORM PULLEY.
[8] Remove the WORM PULLEY.
[9] Remove the 2
Hex SCREWS from the CYCLE SOLENOID.
[10] Remove the CYCLE SOLENOID.
[11] Remove the
Phillips SCREW from the AUTO-FOCUS BRACKET ASSEMBLY.
[12] Pull and remove the AUTO-FOCUS BRACKET ASSEMBLY through the hole where the CYCLE SOLENOID
was.
Installing the AUTO-FOCUS BRACKET ASSEMBLY
[1] Do the replacement procedure for the AUTO-FOCUS BRACKET ASSEMBLY in reverse order.
A091_4023BA
SOLENOID
CYCLE
SCREW
ASSEMBLY
BRACKET
FOCUS
AUTO
SCREW (2)
SCREW
A091_4023BCA
PULLEY
WORM