Kramer Electronics VP-725xl User Manual

Page of 57
Connecting the VP-725xl Presentation Switcher / Scaler 
 
13 
13 
6.2 The RGBS and RGsB PINOUTs 
 defines the input progressive
1
 and interlaced
2
 RGBS and RGsB 
pinouts: 
Table 3: RGBS and RGsB PINOUTS 
Input 
Color Space 
PINOUT 
VGA 
RGsB 
Red to PIN 1 
Green + sync, to PIN 2 
Blue to PIN 3 
 
RGBS 
Red to PIN 1 
Green to PIN 2 
Blue to PIN 3 
Hs (H and V) to PIN 13 
YUV 
YPbPr 
Green + sync to Y 
Blue to Pb 
Red to Pr 
6.3 Connecting to the VP-725xl via RS-232 
You can connect to the unit via a crossed RS-232 connection, using for example, 
a PC. A crossed cable or null-modem is required as shown in method A and B 
respectively. If a shielded cable is used, connect the shield to pin 5. 
Method A (
)—Connect the RS-232 9-pin D-sub port on the unit via a 
crossed cable (pin 
2
 to pin 
3
, pin 
3
 to pin 
2
, and pin 
5
 to pin 
5
) to the RS-232 
9-pin D-sub port on the PC. 
Note: There is no need to connect any other pins. 
 
Figure 4: Crossed Cable RS-232 Connection 
Hardware flow control is not required for this unit. In the rare case where a 
controller requires hardware flow control, short pin 1 to 7 and 8, and pin 4 to 6 
on the controller side. 
Method B (
)—Connect the RS-232 9-pin D-sub port on the unit via a 
straight (flat) cable to the null-modem adapter, and connect the null-modem 
adapter to the RS-232 9-pin D-sub port on the PC. The straight cable usually 
                                                        
1 A display mode in which all the horizontal lines of an image are displayed in a single frame (one field) 
2 A display mode in which a frame consists of two separate fields with the first field consisting of odd horizontal lines and the 
second field even horizontal lines