Page of 208
DM525™ and DM575™ Series Digital Mailing System Operating Guide
SV62201 Rev. C
9 - 5
2. Remove the cap from the 
bottle.
3. Add enough E-Z Seal® to bring 
the level up to the bottom of the 
fill cap. 
4. Replace and tighten the cap and replace the bottle. The nozzle should 
be facing down and the flat side of the bottle facing the front of the sys-
tem. 
5. Close the feed cover. 
Moistener 
Maintenance
This section describes how to clean and/or replace the part of your mailing 
system that moistens the flap on the envelope. This part of the mailing sys-
tem is the moistener brush assembly and consists of the moistener brush, 
moistener wick and moistener tank. 
If the seal quality does not improve after cleaning, you can replace the wick 
or moistener brush as needed. To order replacements, refer to Chapter 11, 
Supplies and Options
 in this guide. Only a Pitney Bowes representative can 
install a new moistener tank.
CAUTION:  Do not overfill the E-Z Seal®  bottle.
CAUTION:  Make sure you do not spill any solution in the 
tape well. If the tape gets wet, it can warp and cause a 
jam. 
CAUTION: Never remove the E-Z Seal® bottle and the 
moistener tank at the same time. This can result in E-Z Seal® 