Xerox 518 Leaflet

Page of 2
XEROX     Trade Name:   ECP-Magenta Toner Premix/Concentrate for ECP 42 
 
 
MSDS No.: A-2006
A
 
 
 
 
 
 
 
Section IV - Physical Data 
 
Appearance/Odor: 
Magenta liquid /slight odor 
Softening Range: N.A. 
Boiling Point: 160 
-180 
oC 
Melting Point: N.A. 
Solubility in Water: Immiscible 
Specific Gravity (H2O=1): 0.77 
Evaporation Rate: 
0.3, (n-Butylacetate = 1) 
Vapor Pressure @20oC  (mm Hg): 
Vapor Density (Air=1): 5.0 
pH: N.A. 
Volatile: 
~100% (Wt.)    N.A. % (Vol.) 
Volatile Organics: 
660- 730 g/l 
 
 
Section V - Fire and Explosion Data 
 
Flash Point (Method Used): 102o-107oF (39-42oC) T.C.C. 
Flammable Limits 
LEL: 0.8%, UEL: 7.0% 
NFPA 704: 
Health - 1, Fire - 2, Reactivity - 1 
Extinguishing Media: 
Foam, dry chemical, CO
2
, water fog. 
Special Fire Fighting Procedures:  Use air-supplied breathing equipment for enclosed areas.  Cool exposed containers with water 
 
spray.  Avoid breathing vapor or fumes.  
Fire and Explosion Hazards: 
Do not mix or store with strong oxidants like liquid chlorine or concentrated oxygen. 
 
 
Section VI -Reactivity Data 
 
Stability: 
 Stable 
Hazardous Polymerization: 
Will Not Occur 
Hazardous Decomposition Products:  Fumes, smoke and carbon monoxide in the case of incomplete combustion. 
Incompatibility (Materials to Avoid):  Strong oxidants such as liquid chlorine, concentrated oxygen, sodium/calcium hypochlorite.  
 
 
Section VII - Special Protection Information 
 
Respiratory Protection:
 
None when used as intended with Xerox Engineering Systems products.  
Eye Protection: 
None when used as intended with Xerox Engineering Systems products.  
Protective Gloves: 
Neoprene or nitrile gloves for prolonged or repeated skin contact. 
Other: 
None when used as intended with Xerox Engineering Systems products.  
 
 
 
 
Section VIII - Special Precautions 
 
Handling and Storage:  Keep container closed.  Avoid handling near heat, strong light, sparks, oxygen flames, strong oxidants. 
Conditions to Avoid: 
Avoid breathing vapors.  Avoid prolonged or repeated skin contact. 
 
 
 
 
Section IX- Spill, Leak, and Disposal Procedures 
 
For Spills or Leakage: 
Remove ignition sources.  Recover free liquid using an absorbent material (vermiculite, fire 
 
retardant, sawdust, etc.). 
Waste Disposal Method: 
The waste toner may be classified as an ignitable hazardous waste under federal and/or state 
 
regulations and should be disposed at an approved disposal site or facility in accordance with federal, 
 
state, and local regulations. 
 
 
 
 
Section X - Transportation Information 
 
 
Proper Shipping Name 
Hazard Class 
ID #   
Packing Group  Exceptions may apply
D.O.T
 
Combustible liquid, n.o.s. 
Combustible
 NA 
1993 III 
 
 Reclassification: 49CFR 173.150 (f) (2) *
 
 
(Isoparaffinic hydrocarbon) 
   liquid 
 
 
 
 
  
I.A.T.A 
Flammable liquid, n.o.s.  
UN 1993 
III 
 
 Y309. 
 (Isoparaffinic 
hydrocarbon)   
I.M.O 
Flammable liquid, n.o.s.  
3 UN 
1993 
III 
 
 3.4 Limited Quantities
 
 (Isoparaffinic 
hydrocarbon)   
 
*Note: This product has been reclassified as a combustible liquid under DOT when shipped domestically by land only.  This product is not regulated by  DOT when 
shipped in non-bulk quantities of less than 119 gallons.  This product is exempt from the Canadian Transportation of Dangerous Goods regulations (section 1.33), when 
transported in containers less than 450 liters and not by air. 
 
 
 
 
 
 
 